Delivering high-precision stainless steel and titanium implants engineered for acute fracture repair, sports medicine reconstruction, and total joint replacement in compliance with US FDA 510(k) and ISO 13485 quality frameworks.
Anatomically contoured total knee joint replacement component crafted from Cobalt-Chromium (CoCrMo) alloy for high resistance to micro-wear.
Get a Quote
Minimally invasive arthroscopic meniscal repair system engineered for low-profile pass through and stable soft-tissue fixation.
Get a Quote
Precision surgical instrumentation tray featuring ergonomic alignment guides, reamers, and bone cuts for predictable joint reconstruction.
Get a Quote
High-strength CoCrMo alloy tibial tray with highly polished stem surface for superior primary stability in total knee arthroplasty (TKA).
Get a Quote
Operating room positioning braces and rigid surgical table attachments designed to optimize joint exposure during complex arthroplasty.
Get a Quote
Sterilizable stainless steel leg distractor and positioner aiding precise joint gap creation during knee arthroscopy and arthroplasty.
Get a Quote
Constrained hinged revision knee prosthesis providing multi-axial stability for bone loss, ligament weakness, and severe joint deformity.
Get a Quote
Biocompatible viscosupplementation gel formulation designed to restore synovial fluidity, decrease friction, and relieve osteoarthritic joint pain.
Get a QuoteUnderstanding why differential thread pitch design and cannulated internal architecture provide superior interfragmentary compression in intra-articular small bone fractures.
The Herbert screw relies on a dual-thread architecture. The leading (distal) threads feature a larger pitch than the trailing (proximal) threads. As the screw is driven across the fracture line, the distal segment advances faster into the bone than the proximal segment, creating powerful dynamic interfragmentary compression without the requirement of a prominent screw head.
By completely countersinking below the articular cartilage plane, Herbert screws eliminate soft-tissue impingement, tendon friction, and localized cartilage erosion. This anatomical profile is critical for scaphoid nonunion, osteochondral fractures, and carpal/tarsal arthrodesis performed across trauma centers in the Bay Area.
Featuring a micro-reamed inner cannulated core, our screws fit over Kirschner wires (K-wires). This allows surgeons to verify trajectory fluoroscopically before reaming and driving the screw, drastically reducing surgical time, bone loss, and intraoperative re-drilling.
Clinical Insight for San Francisco Hand & Upper Extremity Specialists: Primary scaphoid fracture fixation using a headless Herbert cannulated screw provides immediate mechanical rigidity. Clinical studies indicate a union rate exceeding 95% for acute scaphoid waist fractures, allowing earlier wrist mobilization and faster return-to-work timelines for Bay Area tech professionals and active individuals.
| Screw Diameter | Material Grade | Cannulation Core (Ø) | K-Wire Guide (Ø) | Available Lengths | Primary Clinical Indications |
|---|---|---|---|---|---|
| 2.2 mm Micro | Ti-6Al-4V ELI / 316L VM | 0.9 mm | 0.8 mm | 10 mm – 30 mm | Phalangeal, metacarpal, osteochondral fractures & distal radius fragments. |
| 2.7 mm Mini | Ti-6Al-4V ELI / 316L VM | 1.1 mm | 1.0 mm | 12 mm – 40 mm | Scaphoid waist, carpal bones, radial head, distal ulna. |
| 3.0 mm Standard | Ti-6Al-4V ELI / 316L VM | 1.2 mm | 1.1 mm | 14 mm – 50 mm | Acute scaphoid nonunion, capitellum, talus, intercarpal fusion. |
| 4.0 mm Large | Ti-6Al-4V ELI / 316L VM | 1.6 mm | 1.5 mm | 20 mm – 65 mm | Medial malleolus, calcaneus, distal humerus, Lisfranc joint reconstruction. |
| 4.5 mm XL | Ti-6Al-4V ELI / 316L VM | 1.8 mm | 1.6 mm | 25 mm – 80 mm | Tibiotalar fusion, femoral head osteochondritis dissecans, tarsal arthrodesis. |
From Level-1 trauma centers to specialized ambulatory surgical networks across San Francisco, Oakland, and Silicon Valley, our surgical implant systems are designed for high-demand clinical environments.
At major medical institutions such as Zuckerberg San Francisco General Hospital and UCSF Medical Center, high-velocity polytrauma demands rapidly deployable, failsafe implants. Siora’s Herbert screws enable swift percutaneous reduction for complex wrist and ankle fractures.
San Francisco’s outpatient ambulatory centers prioritize procedures with minimal operating times and lower complication rates. Pre-sterilized, cleanroom-packaged cannulated screw sets streamline tray turnaround, reducing instrument prep times by up to 35%.
With an active Bay Area population engaged in cycling, climbing, and competitive athletics, orthopedic specialists frequently treat osteochondral defects of the knee and ankle. Headless screws ensure complete tissue coverage with zero postoperative hardware prominence.
Medical device procurement across the San Francisco Bay Area is shifting toward direct-from-manufacturer partnerships to manage rising supply chain costs while retaining rigorous clinical quality.
Backed by over 35 years of engineering experience, Siora Surgicals Private Limited is a globally recognized manufacturer and exporter of orthopedic implants and trauma systems.
Operating from a modern, CNC-equipped manufacturing unit located in the HSIIDC Industrial Estate (RAI, Sonipat, Haryana), Siora Surgicals combines state-of-the-art multi-axis Swiss sliding-head lathes, vertical machining centers (VMC), and automated surface treatment technology to produce world-class cannulated screws, trauma plates, and joint prostheses.
Siora Surgicals State-of-the-Art ISO 13485 Cleanroom & Manufacturing Facility
Answers to common questions from hospital purchasing officers, orthopedic distributors, and surgical directors in the Bay Area.
Herbert screws feature a headless design that allows complete countersinking beneath the cartilage surface, preventing joint impingement. Their variable thread pitch automatically generates interfragmentary compression during insertion without needing a prominent screw head, leading to faster scaphoid fracture union and earlier mobilization.
We manufacture our cannulated screws using medical-grade Titanium Alloy (Ti-6Al-4V ELI conforming to ASTM F136) for superior MRI compatibility and biocompatibility, as well as Implant-Grade Stainless Steel (316LVM conforming to ASTM F138) for optimal yield strength and rigid fixation.
Yes. Siora Surgicals specializes in OEM and private label manufacturing. We provide custom titanium color anodization (e.g., gold 2.2mm, blue 2.7mm, green 3.0mm), laser etching for SKU branding, and custom-designed sterile pouch or tray packaging for US medical device brands.
We maintain a comprehensive ready-to-dispatch inventory of standard SKUs. Orders dispatched via international express air freight (DHL/FedEx) typically arrive at San Francisco International Airport (SFO) or local Bay Area logistics hubs within 3 to 5 business days.
Every shipment includes Certificates of Conformance (CoC), raw material mill test reports, ISO 13485:2016 certificate copies, CE compliance certification, sterilizer validation documents (where applicable), and detailed commercial invoice documentation for customs clearance.
Yes, we provide complete surgical instrument sets including cannulated hex/torx drivers, countersinks, stepped reamers, depth gauges, and stainless steel Kirschner wires tailored to each specific screw diameter range.
Connect directly with Siora Surgicals' export specialists to discuss bulk hospital pricing, distributor distribution rights in Northern California, or OEM contract manufacturing specifications.
Get a Quote