Explore our comprehensive portfolio of CE & ISO 13485 certified mandibular reconstruction plates, locking/non-locking screws, and surgical instrument kits tailored for OEM/ODM partners and US healthcare providers.
Comprehensive orthopedic tray system equipped with titanium mini-plates, emergency benders, and precision screw drivers for complex jaw trauma.
Ultra-low profile titanium osteotomy plate set designed for orthognathic correction, midface alignment, and delicate mandibular symphysis fixation.
Load-bearing 2.4mm structural reconstruction system engineered for bridging critical segment defects and severe comminuted jaw fractures.
Biocompatible Ti-6Al-4V ELI titanium micro-plates featuring continuous contouring capability for mandibular angle and ramus fixation.
Modular stainless steel surgical tray with customized dynamic force-limiting drivers, plate-bending pliers, and depth gauges.
Threaded locking mechanical connection ensuring angle-stable fixation, reducing primary screw loosening and periosteal compression.
Anatomical mandibular practice model designed for surgical residency training, implant placement pre-planning, and drilling simulation.
Comprehensive biomechanical training system featuring detachable anatomical dentition, TMJ articulation, and soft tissue simulation.
A comprehensive analysis of biomechanical stress distribution, material science selection, and structural stability in craniomaxillofacial defect repair.
Mandibular defect bridging requires high fatigue resistance under cyclical masticatory loading. Siora Surgicals utilizes medical-grade Titanium Alloy (Ti-6Al-4V ELI Grade 23, ASTM F136), offering a yield strength exceeding 860 MPa. This delivers superior tensile capacity compared to Commercially Pure (CP) Titanium, preventing intraoperative fatigue failure during complex microvascular free flap reconstructions.
Traditional non-locking systems depend heavily on plate-to-bone friction, which can induce periosteal ischemia and localized bone resorption. Our locking plate technology utilizes threaded screw heads that lock directly into the plate holes. This creates a rigid construct that functions as an external fixator, preserving periosteal blood supply and ensuring stable fixation across segmental continuity defects.
Facial symmetry and aesthetic restoration require precise plate contouring along the lower border of the mandible. Siora's 2.0mm and 2.4mm reconstruction plates feature smooth rounded edges, low-profile screw heads to prevent soft tissue irritation, and pre-formed anatomic curvature options that reduce bending time during emergency surgical procedures.
The selection of plate profile and screw diameter must correspond directly to the anatomical region and structural defect type. Below is an engineering overview of our OEM/ODM CMF reconstruction matrix.
| System Category | Plate Thickness | Screw Diameter Range | Material Standard | Primary Clinical Application | Biomechanical Profile |
|---|---|---|---|---|---|
| 1.5mm Micro System | 0.6mm – 1.0mm | 1.5mm – 1.8mm Emergency | ASTM F136 Ti-6Al-4V | Midface fractures, orbital rim repair, pediatric CMF | Low profile, malleable, zero functional force loading |
| 2.0mm Mini System | 1.0mm – 1.5mm | 2.0mm – 2.3mm Emergency | ASTM F136 / ISO 5832-3 | Mandibular angle/symphysis fractures, orthognathic osteotomies | Semi-rigid, preservesChampy's ideal line of osteosynthesis |
| 2.4mm Reconstruction System | 2.0mm – 2.8mm | 2.4mm – 2.7mm Emergency | ASTM F136 Grade 23 Ti | Segmental defect repair, fibular free flap bridging, tumor resection | Full load-bearing, dynamic structural stability under mastication |
| Custom CAD/CAM PSI System | Patient-Specific (1.5–3.0mm) | 2.0mm / 2.4mm Locking | Additive Ti-6Al-4V Grade 23 | Complex oncologic resections, facial asymmetry correction | Anatomically matched stress distribution via FEA optimization |
Siora Surgicals provides comprehensive OEM/ODM supply chain solutions, leveraging state-of-the-art CNC precision machining, ISO cleanrooms, and robust FDA regulatory technical support.
Our manufacturing facility in Rai, Sonepat is equipped with advanced 5-axis CNC sliding-head lathes, high-precision Swiss-type turning centers, and Vertical Machining Centers (VMC). This precision infrastructure allows us to achieve strict manufacturing tolerances (+/- 0.005mm) required for intricate locking screw threads and complex plate geometries.
Implant safety starts with absolute contamination control. Siora operates dedicated ISO Class 7 validated cleanrooms for ultrasonic cleaning, automated anodization, and primary packaging. Every OEM component undergoes validated washing protocols to ensure endotoxin levels remain well below US FDA regulatory thresholds.
Navigating US FDA clearance requires complete metallurgical traceability and testing documentation. We provide OEM contract partners with complete Device Master Files (DMF), inclusive of ASTM F136 raw material certificates, mechanical fatigue testing (ISO 14801 / ASTM F382), and ISO 10993 biocompatibility compliance data.
From Level-1 trauma centers to academic medical centers, Siora's mandibular reconstruction hardware seamlessly integrates into standard US surgical workflows.
In oral squamous cell carcinoma cases requiring radical mandibulectomy, surgeons utilize microvascular fibular free flaps (FFF) to rebuild the jaw arch. Siora’s 2.4mm load-bearing reconstruction plates provide the structural backbone needed to bridge the osteotomy gaps and fixate the transferred vascularized bone grafts safely.
Level-1 US Trauma Centers frequently manage severe motor vehicle collision (MVC) facial trauma involving comminuted mandibular body and angle fractures. Our dynamic multi-hole plates allow rapid intraoperative adaptation, providing immediate rigid compression across fracture lines.
For patients undergoing bilateral sagittal split osteotomy (BSSO) or Le Fort procedures to correct malocclusion, Siora’s 2.0mm mini-plate systems offer rigid fixation with minimal soft-tissue displacement, supporting rapid bone healing and post-operative recovery.
US academic institutions and surgical training facilities utilize our anatomical mandibular practice models featuring soft silicone gums and TMJ articulation. These models allow residents to master drilling angle vectoring, plate contouring, and screw insertion without risking clinical outcomes.
Key technological shifts and economic drivers shaping the future of craniomaxillofacial implant procurement across North America.
US oral and maxillofacial surgeons increasingly rely on preoperative 3D Virtual Surgical Planning based on high-resolution CT DICOM data. Contract manufacturers must support CAD/CAM file transfer to produce patient-specific surgical guides and pre-bent reconstruction plates that significantly reduce operating room (OR) time.
Rising healthcare expenditures in the US have intensified pressure on hospital procurement departments to optimize device spending. US medical distributors are partnering with overseas ISO 13485 certified OEM manufacturers like Siora Surgicals to source high-quality, cost-effective CMF systems without compromising metallurgical integrity.
Hospitals are moving away from bloated inventory toward procedure-specific bio-kits. Siora's modular CMF kit boxes streamline sterilization logistics, reduce central sterile processing costs, and ensure all necessary plate configurations and instruments are readily available during emergency trauma interventions.
Addressing key technical, regulatory, and supply chain queries regarding OEM contract manufacturing and importation of mandibular hardware.
Siora Surgicals provides comprehensive technical dossiers to support our OEM partners' 510(k) submissions. This documentation includes raw material inspection reports conforming to ASTM F136 / ASTM F67, biomechanical fatigue test data (axial tension, bending stiffness), ISO 10993 biocompatibility testing, cleanroom bioburden validation, and complete Device History Records (DHR).
Yes. We offer contract OEM/ODM custom manufacturing services capable of translating 3D CAD models (STL/STEP files derived from patient CT scans) into patient-specific mandibular plates and surgical cutting guides using 5-axis CNC machining and selective laser melting (SLM) additive techniques.
Our screws feature standardized internal hex and Star/Torx drive recesses compatible with industry-standard surgical instrument connections. We also manufacture custom ergonomic screw drivers and holding sleeves as part of complete system OEM contract packages.
All titanium components undergo multi-stage automated ultrasonic cleaning using deionized water, followed by passivation and Type II anodization. Final packaging takes place inside our ISO Class 7 cleanrooms, ensuring zero surface particulate contamination prior to Gamma irradiation or steam sterilization.
Standard implant production runs typically ship within 30 to 45 days upon order confirmation. For stocking distributors requiring immediate delivery, Siora maintains a broad inventory of standard 1.5mm, 2.0mm, and 2.4mm CMF plates and screws ready for rapid global dispatch.
Expand your CMF product portfolio with high-precision, medical-grade titanium mandibular reconstruction systems manufactured in compliance with international quality standards.